Electrode weighing

From KIproBatt Wiki
< 220714-kaop-0300-piLabObject:OSLb6cbb42dac874f20bc37c2c860909880/S0020
220714-kaop-0300-piElectrode weighing
m (Append data)
m (Append data)
 
Line 7: Line 7:
 
|output_objects=O0000
 
|output_objects=O0000
 
|start_date=2022-07-14T08:31:59.000Z
 
|start_date=2022-07-14T08:31:59.000Z
|end_date=2022-07-14T08:31:59.000Z
+
|end_date=2022-07-14T08:56:23.991Z
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512
+
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|precondition_fulfilled=No
 
|precondition_fulfilled=No
 
|postcondition_fulfilled=No
 
|postcondition_fulfilled=No

Latest revision as of 09:56, 14 July 2022


Prozessschritt Electrode weighing

Prozessschritt Electrode weighing des Laborprozesses 220714-kaop-0300-pi wurde von Kai Oppel bearbeitet und folgt(e) auf Electrode Foil Separation bzw. lief parallel zu . Die Bearbeitung wurde am 2022-07-14T08:31:59.000Z begonnen und am 2022-07-14T08:56:23.991Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: 220714-kaop-0300-pi.

Ausgangsobjekte: 220714-kaop-0300-pi.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Dosing device <707c359d>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Category:Object) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Selected camera weighing scaleElectrode weighingCameraWeighingScaleParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Satorius Cam Weighing Scale
CamScale 1 (TKIII 004)
Electrode image 1Electrode weighingElectrode1ElectrodeImage1Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLb6cbb42dac874f20bc37c2c860909880O0001.jpeg
Electrode image 2Electrode weighingElectrode1ElectrodeImage2Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLb6cbb42dac874f20bc37c2c860909880O0002.jpeg
Electrode image 3Electrode weighingElectrode1ElectrodeImage3Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLb6cbb42dac874f20bc37c2c860909880O0003.jpeg
Electrode image 4Electrode weighingElectrode1ElectrodeImage4Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLb6cbb42dac874f20bc37c2c860909880O0004.jpeg
Electrode image 5Electrode weighingElectrode1ElectrodeImage5Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLb6cbb42dac874f20bc37c2c860909880O0005.jpeg
Predrying mass 1Electrode weighingElectrode1PredryingMass1Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6422 g
Predrying mass 2Electrode weighingElectrode1PredryingMass2Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6431 g
Predrying mass 3Electrode weighingElectrode1PredryingMass3Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6468 g
Predrying mass 4Electrode weighingElectrode1PredryingMass4Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6461 g
Predrying mass 5Electrode weighingElectrode1PredryingMass5Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6436 g

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage