Electrode weighing

From KIproBatt Wiki
< 220714-kaop-1700-piLabObject:OSL01f0a7af400e46668908d1e82031d2c6/S0020
220714-kaop-1700-piElectrode weighing
m (Append data)
m (Append data)
 
(9 intermediate revisions by the same user not shown)
Line 7: Line 7:
 
|output_objects=O0000
 
|output_objects=O0000
 
|start_date=2022-07-14T10:55:36.000Z
 
|start_date=2022-07-14T10:55:36.000Z
|end_date=2022-07-14T10:55:36.000Z
+
|end_date=2022-07-14T11:04:33.543Z
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512
+
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|precondition_fulfilled=No
 
|precondition_fulfilled=No
 
|postcondition_fulfilled=No
 
|postcondition_fulfilled=No
Line 43: Line 43:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.5071
+
|actual_value=0.5069
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0002
 
|object_id=O0002
Line 57: Line 57:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.5055
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0003
 
|object_id=O0003
Line 70: Line 71:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.5074
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0004
 
|object_id=O0004
Line 83: Line 85:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.5059
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0005
 
|object_id=O0005
Line 96: Line 99:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.5065
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0006
 
|object_id=O0006
Line 109: Line 113:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.506
 
}}
 
}}
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
Line 135: Line 140:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL01f0a7af400e46668908d1e82031d2c6O0002.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|object_id=O0003
 
|object_id=O0003
Line 146: Line 152:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL01f0a7af400e46668908d1e82031d2c6O0003.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|object_id=O0004
 
|object_id=O0004
Line 157: Line 164:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL01f0a7af400e46668908d1e82031d2c6O0004.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|object_id=O0005
 
|object_id=O0005
Line 168: Line 176:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL01f0a7af400e46668908d1e82031d2c6O0005.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|object_id=O0006
 
|object_id=O0006
Line 179: Line 188:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL01f0a7af400e46668908d1e82031d2c6O0006.jpeg
 
}}
 
}}
 
}}
 
}}

Latest revision as of 12:04, 14 July 2022


Prozessschritt Electrode weighing

Prozessschritt Electrode weighing des Laborprozesses 220714-kaop-1700-pi wurde von Kai Oppel bearbeitet und folgt(e) auf Electrode Foil Separation bzw. lief parallel zu . Die Bearbeitung wurde am 2022-07-14T10:55:36.000Z begonnen und am 2022-07-14T11:04:33.543Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: 220714-kaop-1700-pi.

Ausgangsobjekte: 220714-kaop-1700-pi.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Dosing device <707c359d>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Category:Object) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Selected camera weighing scaleElectrode weighingCameraWeighingScaleParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Satorius Cam Weighing Scale
CamScale 1 (TKIII 004)
Electrode image 1Electrode weighingElectrode1ElectrodeImage1Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL01f0a7af400e46668908d1e82031d2c6O0001.jpeg
Electrode image 2Electrode weighingElectrode1ElectrodeImage2Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL01f0a7af400e46668908d1e82031d2c6O0002.jpeg
Electrode image 3Electrode weighingElectrode1ElectrodeImage3Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL01f0a7af400e46668908d1e82031d2c6O0003.jpeg
Electrode image 4Electrode weighingElectrode1ElectrodeImage4Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL01f0a7af400e46668908d1e82031d2c6O0004.jpeg
Electrode image 5Electrode weighingElectrode1ElectrodeImage5Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL01f0a7af400e46668908d1e82031d2c6O0005.jpeg
Electrode image 6Electrode weighingElectrode1ElectrodeImage6Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL01f0a7af400e46668908d1e82031d2c6O0006.jpeg
Predrying mass 1Electrode weighingElectrode1PredryingMass1Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5069 g
Predrying mass 2Electrode weighingElectrode1PredryingMass2Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5055 g
Predrying mass 3Electrode weighingElectrode1PredryingMass3Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5074 g
Predrying mass 4Electrode weighingElectrode1PredryingMass4Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5059 g
Predrying mass 5Electrode weighingElectrode1PredryingMass5Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5065 g
Predrying mass 6Electrode weighingElectrode1PredryingMass6Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.506 g

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage