Drying

From KIproBatt Wiki
< 230908-gron-0400-piLabObject:OSL28caabf5dc2144d0a917f4b3cf1ad870/S0010
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
 
|agent=Andreas Gronbach
 
|agent=Andreas Gronbach
 
|output_objects=O0001
 
|output_objects=O0001
|start_date=2023-09-26T05:40:00.000Z
+
|start_date=2023-09-26T04:00:00.000Z
|end_date=2023-09-27T07:00:00.000Z
+
|end_date=2023-09-27T04:30:00.000Z
 
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|comment=DOE2 Drying 24 h
 
|comment=DOE2 Drying 24 h
 +
in Schleuse LiB#9 getrocknet (nicht X-Shleuse)
 
|precondition_fulfilled=No
 
|precondition_fulfilled=No
 
|postcondition=Check correct start and end time!
 
|postcondition=Check correct start and end time!
Line 149: Line 150:
 
|nominal_value=50
 
|nominal_value=50
 
|nominal_unit=mbar
 
|nominal_unit=mbar
|actual_value=15
+
|actual_value=50
 
|actual_unit=mbar
 
|actual_unit=mbar
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative

Latest revision as of 08:13, 27 September 2023


Prozessschritt Drying

Prozessschritt Drying des Laborprozesses 230908-gron-0400-pi wurde von Andreas Gronbach bearbeitet und folgt(e) auf Magazine Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2023-09-26T04:00:00.000Z begonnen und am 2023-09-27T04:30:00.000Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 230908-gron-0400-pi.


Die Nachbedingung Check correct start and end time! wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Heizgerät <efbb17cf>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Elektrodenmagazin <b1415173>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Device selectionDryingDryingDeviceSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Glovebox-Schleuse
DurationDryingDurationParameter/Actual
Parameter/Quantitative
Duration24 h
Magazine selection 1Drying230908-gron-0401-miMagazineSelection1Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0157-mi
Magazine selection 2Drying230908-gron-0402-miMagazineSelection2Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0158-mi
Magazine selection 3Drying230908-gron-0403-miMagazineSelection3Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0159-mi
Magazine selection 4Drying230908-gron-0404-miMagazineSelection4Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0160-mi
Magazine selection 5Drying230908-gron-0405-miMagazineSelection5Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0161-mi
Magazine selection 6Drying230908-gron-0406-miMagazineSelection6Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0162-mi
Magazine selection 7Drying230908-gron-0407-miMagazineSelection7Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0163-mi
Magazine selection 8Drying230908-gron-0408-miMagazineSelection8Parameter/Actual
Parameter/InputObject
HasPredecessor230905-gron-0164-mi
Number of ventilationsDryingNumberOfVentilationsParameter/Actual
Parameter/Quantitative
Count5
PressureDryingPressureParameter/Actual
Parameter/Quantitative
Pressure50 mbar
TemperatureDryingTemperatureDrying/Temperature
Parameter/Actual
Parameter/Quantitative
Temperature110 °C
Ventilation pressureDryingVentilationPressureParameter/Actual
Parameter/Quantitative
Pressure500 mbar