Stacking

From KIproBatt Wiki
< 240822-hemue-1200-piLabObject:OSLe19138ba56ff49a6a8f37a4036331f77/S0010
m (Append data)
m (Append data)
 
(20 intermediate revisions by the same user not shown)
Line 6: Line 6:
 
|output_objects=O0000
 
|output_objects=O0000
 
|start_date=2024-08-27T09:25:31.784Z
 
|start_date=2024-08-27T09:25:31.784Z
|end_date=2024-08-22T14:26:46.000Z
+
|end_date=2024-08-27T09:41:32.323Z
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512
+
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|precondition=Check PLC Setting Camera on, correct electrode count
 
|precondition=Check PLC Setting Camera on, correct electrode count
 
|precondition_fulfilled=No
 
|precondition_fulfilled=No
Line 82: Line 82:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.25500000000000256
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0103
 
|object_id=O0103
Line 95: Line 96:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.30510000000000304
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0104
 
|object_id=O0104
Line 108: Line 110:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.24929999999999808
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0105
 
|object_id=O0105
Line 121: Line 124:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.2720999999999947
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0106
 
|object_id=O0106
Line 134: Line 138:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.2546999999999997
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0107
 
|object_id=O0107
Line 147: Line 152:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.2880000000000038
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0108
 
|object_id=O0108
Line 160: Line 166:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.254800000000003
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0109
 
|object_id=O0109
Line 173: Line 180:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.2967000000000013
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0110
 
|object_id=O0110
Line 186: Line 194:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.24960000000000093
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0111
 
|object_id=O0111
Line 199: Line 208:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.2813999999999979
 
}}
 
}}
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
Line 223: Line 233:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0002.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 233: Line 244:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0003.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 243: Line 255:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0004.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 253: Line 266:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0005.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 263: Line 277:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0006.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 273: Line 288:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0007.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 283: Line 299:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0008.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 293: Line 310:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0009.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 303: Line 321:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0010.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 313: Line 332:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLe19138ba56ff49a6a8f37a4036331f77S0010P0011.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6

Latest revision as of 10:41, 27 August 2024


Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 240822-hemue-1200-pi wurde von Hendrik Müller bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2024-08-27T09:25:31.784Z begonnen und am 2024-08-27T09:41:32.323Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 240822-hemue-1200-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0001.jpeg
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0002.jpeg
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0003.jpeg
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0004.jpeg
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0005.jpeg
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0006.jpeg
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0007.jpeg
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0008.jpeg
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0009.jpeg
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0010.jpeg
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLe19138ba56ff49a6a8f37a4036331f77S0010P0011.jpeg
Electrode image 12StackingElectrodeImage12Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 13StackingElectrodeImage13Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 14StackingElectrodeImage14Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 15StackingElectrodeImage15Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 16StackingElectrodeImage16Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 17StackingElectrodeImage17Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 18StackingElectrodeImage18Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 19StackingElectrodeImage19Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 20StackingElectrodeImage20Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 21StackingElectrodeImage21Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 22StackingElectrodeImage22Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Predrying mass 01Stacking240822-hemue-1200-piPredryingMass01Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.2903999999999982 g
Predrying mass 02Stacking240822-hemue-1200-piPredryingMass02Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.25500000000000256 g
Predrying mass 03Stacking240822-hemue-1200-piPredryingMass03Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.30510000000000304 g
Predrying mass 04Stacking240822-hemue-1200-piPredryingMass04Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.24929999999999808 g
Predrying mass 05Stacking240822-hemue-1200-piPredryingMass05Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.2720999999999947 g
Predrying mass 06Stacking240822-hemue-1200-piPredryingMass06Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.2546999999999997 g
Predrying mass 07Stacking240822-hemue-1200-piPredryingMass07Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.2880000000000038 g
Predrying mass 08Stacking240822-hemue-1200-piPredryingMass08Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.254800000000003 g
Predrying mass 09Stacking240822-hemue-1200-piPredryingMass09Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.2967000000000013 g
Predrying mass 10Stacking240822-hemue-1200-piPredryingMass10Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.24960000000000093 g
Predrying mass 11Stacking240822-hemue-1200-piPredryingMass11Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.2813999999999979 g
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage