Stacking

From KIproBatt Wiki
< 241205-gron-0600-piLabObject:OSL0adfdc75a8304e11aa14c62a317ed188/S0010
m (Append data)
Line 5: Line 5:
 
|agent=Andreas Gronbach
 
|agent=Andreas Gronbach
 
|output_objects=O0000
 
|output_objects=O0000
|start_date=2024-12-05T15:48:48.000Z
+
|start_date=2024-12-09T15:32:04.719Z
 
|end_date=2024-12-05T15:48:49.000Z
 
|end_date=2024-12-05T15:48:49.000Z
 
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512
 
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512

Revision as of 16:32, 9 December 2024


Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 241205-gron-0600-pi wurde von Andreas Gronbach bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2024-12-09T15:32:04.719Z begonnen und am 2024-12-05T15:48:49.000Z beendet.(Status: Pending <aa8d2940>)

Eingangsobjekte: .

Ausgangsobjekte: 241205-gron-0600-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0001.jpeg
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0002.jpeg
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0003.jpeg
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0004.jpeg
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0005.jpeg
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0006.jpeg
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0007.jpeg
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0008.jpeg
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0009.jpeg
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0010.jpeg
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0011.jpeg
Electrode image 12StackingElectrodeImage12Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0012.jpeg
Electrode image 13StackingElectrodeImage13Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0013.jpeg
Electrode image 14StackingElectrodeImage14Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0014.jpeg
Electrode image 15StackingElectrodeImage15Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0015.jpeg
Electrode image 16StackingElectrodeImage16Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0016.jpeg
Electrode image 17StackingElectrodeImage17Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0017.jpeg
Electrode image 18StackingElectrodeImage18Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0018.jpeg
Electrode image 19StackingElectrodeImage19Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0019.jpeg
Electrode image 20StackingElectrodeImage20Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0020.jpeg
Electrode image 21StackingElectrodeImage21Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL0adfdc75a8304e11aa14c62a317ed188S0010P0021.jpeg
Electrode image 22StackingElectrodeImage22Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Predrying mass 01Stacking241205-gron-0600-piPredryingMass01Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 02Stacking241205-gron-0600-piPredryingMass02Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.3204 g
Predrying mass 03Stacking241205-gron-0600-piPredryingMass03Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 04Stacking241205-gron-0600-piPredryingMass04Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.3173 g
Predrying mass 05Stacking241205-gron-0600-piPredryingMass05Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 06Stacking241205-gron-0600-piPredryingMass06Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.31799999999999995 g
Predrying mass 07Stacking241205-gron-0600-piPredryingMass07Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 08Stacking241205-gron-0600-piPredryingMass08Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.3173999999999999 g
Predrying mass 09Stacking241205-gron-0600-piPredryingMass09Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 10Stacking241205-gron-0600-piPredryingMass10Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.3167000000000002 g
Predrying mass 11Stacking241205-gron-0600-piPredryingMass11Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage