Difference between revisions of "LabProcess:220330-sist-0100-pt"

From KIproBatt Wiki
LabProcess:220330-sist-0100-pt
(change unit to g)
Tag: 2017 source edit
m (Text replacement - "220330-sist-0001-di" to "OSLf7e62edcf0e64084a0d92ff0f7a9efe8")
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
 
{{OslTemplate:LabProcess/Header
 
{{OslTemplate:LabProcess/Header
 
  |name=KIproBatt v1 Filling
 
  |name=KIproBatt v1 Filling
  |output_category=Category:220221-sist-0002-mc
+
  |output_category=Category:OSLd83db70a5bf746fb9126d84eb9f6366d
 
  |output_type=
 
  |output_type=
 
  |debug={{OslTemplate:Helper/Strings/No}}
 
  |debug={{OslTemplate:Helper/Strings/No}}
Line 38: Line 38:
 
       |index=1
 
       |index=1
 
       |param_name=CellCount
 
       |param_name=CellCount
       |nominal_quantity=Property:Number
+
       |nominal_quantity=Property:HasNumberOfEntities
 
       |nominal_value=
 
       |nominal_value=
 
       |nominal_unit=
 
       |nominal_unit=
Line 56: Line 56:
 
     {{OslTemplate:LabProcess/Object/ObjectCreator
 
     {{OslTemplate:LabProcess/Object/ObjectCreator
 
       |name=FilledCell
 
       |name=FilledCell
       |type={{{output_type|Material:220330-sist-0001-mt}}}
+
       |type={{{output_type|Material:OSLbe31a19a3a134e249e5435a074757597}}}
 
       |count={{OslTemplate:LabProcess/Query/Param |param_name=CellCount |default=3}}
 
       |count={{OslTemplate:LabProcess/Query/Param |param_name=CellCount |default=3}}
       }}
+
       |global={{OslTemplate:Helper/Strings/Yes}}
 +
    }}
 
   |description=
 
   |description=
   |nominal_object_category=Category:220515-sist-0001-mc
+
   |nominal_object_category=Category:Material
 
   |objects=
 
   |objects=
 
     {{OslTemplate:LabProcess/Parameter/MultiObject/Config
 
     {{OslTemplate:LabProcess/Parameter/MultiObject/Config
Line 67: Line 68:
 
       |param_label=Electrolyte selection
 
       |param_label=Electrolyte selection
 
       |object_id={{OslTemplate:LabProcess/Object/Id |id_postfix=90-mi}}
 
       |object_id={{OslTemplate:LabProcess/Object/Id |id_postfix=90-mi}}
 +
      |nominal_category=Category:OSL0cdd7b45aa6a47fdbf8ca9e7ddc06531
 
     }}
 
     }}
 
     {{OslTemplate:LabProcess/Parameter/MultiObject/ParamArray  
 
     {{OslTemplate:LabProcess/Parameter/MultiObject/ParamArray  
Line 73: Line 75:
 
       |param_name=CellSelection
 
       |param_name=CellSelection
 
       |param_label=Cell selection
 
       |param_label=Cell selection
 +
      |nominal_category=Category:OSLf034e81cd50d4e9ba8e9e31215d39ff0
 
     }}
 
     }}
<!-- [1][object_id]=PouchFoil;[1][name]=PouchFoil;[1][nominal_type]=Material:220330-sist-0002-mt;[1][nominal_instance]=;[1][actual_type]=;
+
<!-- [1][object_id]=PouchFoil;[1][name]=PouchFoil;[1][nominal_type]=Material:OSLd6897689b4ab4d0abfbe73dca741de31;[1][nominal_instance]=;[1][actual_type]=;
           [2][object_id]=CurrentCollector;[2][name]=CurrentCollector;[2][nominal_type]=Material:220330-sist-0003-mt;[2][nominal_instance]=;[2][actual_type]=;
+
           [2][object_id]=CurrentCollector;[2][name]=CurrentCollector;[2][nominal_type]=Material:OSL4203630bca484521b91d11be1bd04f73;[2][nominal_instance]=;[2][actual_type]=;
           [3][object_id]=ElectrodeStack;[3][name]=ElectrodeStack;[3][nominal_type]=Material:220221-sist-0002-mt;[3][nominal_instance]=;[3][actual_type]=; -->
+
           [3][object_id]=ElectrodeStack;[3][name]=ElectrodeStack;[3][nominal_type]=Material:OSL344e5c0f20e04894abe53678e2f68351;[3][nominal_instance]=;[3][actual_type]=; -->
   |nominal_device_category=Category:220330-sist-0001-dc
+
   |nominal_device_category=Category:OSL707c359d5b3d43e480458bc0da142359
 
   |tools=
 
   |tools=
 
     {{OslTemplate:LabProcess/Parameter/MultiTool/Config
 
     {{OslTemplate:LabProcess/Parameter/MultiTool/Config
 
       |index=1
 
       |index=1
 
       |param_name=FillingDevice
 
       |param_name=FillingDevice
       |nominal_category=Category:220330-sist-0001-dc
+
       |nominal_category=Category:OSL707c359d5b3d43e480458bc0da142359
       |nominal_type=Device:220330-sist-0001-dt
+
       |nominal_type=Device:OSL8f44538e3f1247b3a40422054c664a14
       |nominal_instance=LabObject:220330-sist-0001-di
+
       |nominal_instance=LabObject:OSLf7e62edcf0e64084a0d92ff0f7a9efe8
 
       |actual_category_sync_active=No
 
       |actual_category_sync_active=No
 
     }}
 
     }}
Line 90: Line 93:
 
       |index=2
 
       |index=2
 
       |param_name=GloveboxDevice
 
       |param_name=GloveboxDevice
       |nominal_category=Category:220403-sist-0001-dc
+
       |nominal_category=Category:OSLa88e409a039f4e81bd8a1fa4c7f14295
 
       |nominal_type=
 
       |nominal_type=
 
       |nominal_instance=
 
       |nominal_instance=

Latest revision as of 11:46, 26 June 2022

Zur Erstellung von -nicht festgelegt- (Stoffklasse: Filled cell <d83db70a>)

Dies ist nur die Vorlage. Zum Ausfüllen zunächst einen Kopie mit folgendem Button erstellen!


Vorschrift




Cell Count Determination

Generischer Prozessschritt

Parameter

Filling

Generischer Prozessschritt

Parameter

Produkte

 IDTyp
FilledCell 1220330-sist-0101-miFilled cell (KIproBatt v1)
FilledCell 2220330-sist-0102-miFilled cell (KIproBatt v1)
FilledCell 3220330-sist-0103-miFilled cell (KIproBatt v1)


Erstellte Instanzen