Cell manufacturing/Aging
From KIproBatt Wiki
< Battery value chain | Process | Cell manufacturingBattery value chain/Process/Cell manufacturing/Aging
(Created page with "{{Semantic Element |label=Cell manufacturing/Aging |description===Production process== *Aging represents the final step in cell production and is used for quality assurance...") |
Simon Stier (talk | contribs) m (Text replacement - "Has predecessor" to "HasPredecessor") |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | {{Semantic Element | + | {{GlossaryEntry}}{{Semantic Element |
|label=Cell manufacturing/Aging | |label=Cell manufacturing/Aging | ||
− | |description===Production process== | + | |description= |
+ | ====Production process==== | ||
− | * | + | *Final step in cell production |
− | * | + | *Process aims at for quality assurance |
− | * | + | *Cell characteristics performance are monitored over a period of up to three weeks: Regular measurment of open circuit voltage (OCV) |
− | * | + | *Aging differentiation: High temperature (HT) and normal temperature (NT) aging; usual againg sequence: first, HT aging and, then, NT aging |
− | *No significant change in the cell properties over the entire period of time | + | *Storage in so-called aging shelves and/or towers |
− | * | + | *Quality assurance: No significant change in the cell properties over the entire period of time |
− | + | *Aging duration depends strongly on cell manufacturer and used chemistry | |
− | ==Process parameters & requirements== | + | ====Process parameters & requirements==== |
*State of charge of the cell at the beginning of aging: 80 % - 100 % SOC | *State of charge of the cell at the beginning of aging: 80 % - 100 % SOC | ||
Line 17: | Line 18: | ||
*Normal temperature approx. 22°C, high temperature approx. 30°C - 50°C | *Normal temperature approx. 22°C, high temperature approx. 30°C - 50°C | ||
− | ==Technology alternatives== | + | ====Technology alternatives==== |
− | * | + | *Different procedures for sequence and duration of HT and NT aging (depending on cell manufacturer chemistry). |
− | ==Quality influences== | + | ====Quality influences==== |
*Orientation of cells | *Orientation of cells | ||
Line 27: | Line 28: | ||
*Ambient temperature | *Ambient temperature | ||
− | ==Quality features== | + | ====Quality features==== |
*Capacity | *Capacity | ||
Line 33: | Line 34: | ||
*Self-discharge rate | *Self-discharge rate | ||
− | ==Source== | + | ====Source==== |
Heimes, H.H.; Kampker, A.; Lienemann, C.; Locke, M.; Offermanns, C.; Michaelis, S.; Rahimzei, E. (2018) ''Lithium-Ion Battery Cell Production Process''; PEM of RWTH Aachen and VDMA, 3rd Edition, ISBN:978-3-947920-03-7 | Heimes, H.H.; Kampker, A.; Lienemann, C.; Locke, M.; Offermanns, C.; Michaelis, S.; Rahimzei, E. (2018) ''Lithium-Ion Battery Cell Production Process''; PEM of RWTH Aachen and VDMA, 3rd Edition, ISBN:978-3-947920-03-7 | ||
|relations={{Semantic Link | |relations={{Semantic Link | ||
− | |property= | + | |property=HasPredecessor |
|value=Battery value chain/Process/Cell manufacturing/Degassing | |value=Battery value chain/Process/Cell manufacturing/Degassing | ||
+ | }}{{Semantic Link | ||
+ | |property=HasSuccessor | ||
+ | |value=Battery value chain/Process/Cell manufacturing/EOL Testing | ||
}} | }} | ||
}} | }} |
Latest revision as of 04:17, 4 September 2022
Description
Production process
- Final step in cell production
- Process aims at for quality assurance
- Cell characteristics performance are monitored over a period of up to three weeks: Regular measurment of open circuit voltage (OCV)
- Aging differentiation: High temperature (HT) and normal temperature (NT) aging; usual againg sequence: first, HT aging and, then, NT aging
- Storage in so-called aging shelves and/or towers
- Quality assurance: No significant change in the cell properties over the entire period of time
- Aging duration depends strongly on cell manufacturer and used chemistry
Process parameters & requirements
- State of charge of the cell at the beginning of aging: 80 % - 100 % SOC
- Aging time: up to 3 weeks
- Normal temperature approx. 22°C, high temperature approx. 30°C - 50°C
Technology alternatives
- Different procedures for sequence and duration of HT and NT aging (depending on cell manufacturer chemistry).
Quality influences
- Orientation of cells
- Packing density of the cell good carriers
- Ambient temperature
Quality features
- Capacity
- Internal resistance
- Self-discharge rate
Source
Heimes, H.H.; Kampker, A.; Lienemann, C.; Locke, M.; Offermanns, C.; Michaelis, S.; Rahimzei, E. (2018) Lithium-Ion Battery Cell Production Process; PEM of RWTH Aachen and VDMA, 3rd Edition, ISBN:978-3-947920-03-7
Semantic Links
Add or edit outgoing links
To edit incoming links, go to the subjects site.
Outgoing
Subject | Property | Object |
---|---|---|
Cell manufacturing/Aging | HasPredecessor | Cell manufacturing/Degassing |
Cell manufacturing/Aging | HasSuccessor | Cell manufacturing/EOL Testing |