Line 6: Line 6:
 
|output_objects=O0000
 
|output_objects=O0000
 
|start_date=2023-07-18T13:27:16.646Z
 
|start_date=2023-07-18T13:27:16.646Z
|end_date=2023-07-18T08:51:43.000Z
+
|end_date=2023-07-18T13:33:04.225Z
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512
+
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|comment=DOE Drying 17,1h, Coating error medium (3 electrodes), offset (horizontal) 0,29mm
 
|comment=DOE Drying 17,1h, Coating error medium (3 electrodes), offset (horizontal) 0,29mm
 
|precondition=Check PLC Setting Camera on, correct electrode count
 
|precondition=Check PLC Setting Camera on, correct electrode count
Line 170: Line 170:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.6493
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0109
 
|object_id=O0109
Line 183: Line 184:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.46519999999999984
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0110
 
|object_id=O0110
Line 196: Line 198:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.659
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0111
 
|object_id=O0111
Line 209: Line 212:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.5021
 
}}
 
}}
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
Line 387: Line 391:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0016.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 397: Line 402:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0017.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 407: Line 413:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0018.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 417: Line 424:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0019.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 427: Line 435:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0020.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 437: Line 446:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0021.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
 
|type=Term:OSLa5d9516a6a4d40cfbc0b3494e608f7d6
Line 447: Line 457:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSL730f57706e8c4a9bb507931d5d597fadS0010P0022.jpeg
 
}}
 
}}
 
}}
 
}}

Latest revision as of 14:33, 18 July 2023


Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 230718-jajo-0600-pi wurde von Jannis Johann bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2023-07-18T13:27:16.646Z begonnen und am 2023-07-18T13:33:04.225Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 230718-jajo-0600-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor230627-gron-0802-mi
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor230627-gron-0806-mi
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0001.jpeg
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0002.jpeg
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0003.jpeg
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0004.jpeg
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0005.jpeg
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0006.jpeg
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0007.jpeg
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0008.jpeg
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0009.jpeg
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0010.jpeg
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0011.jpeg
Electrode image 12StackingElectrodeImage12Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0012.jpeg
Electrode image 13StackingElectrodeImage13Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0013.jpeg
Electrode image 14StackingElectrodeImage14Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0014.jpeg
Electrode image 15StackingElectrodeImage15Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0015.jpeg
Electrode image 16StackingElectrodeImage16Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0016.jpeg
Electrode image 17StackingElectrodeImage17Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0017.jpeg
Electrode image 18StackingElectrodeImage18Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0018.jpeg
Electrode image 19StackingElectrodeImage19Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0019.jpeg
Electrode image 20StackingElectrodeImage20Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0020.jpeg
Electrode image 21StackingElectrodeImage21Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0021.jpeg
Electrode image 22StackingElectrodeImage22Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL730f57706e8c4a9bb507931d5d597fadS0010P0022.jpeg
Predrying mass 01Stacking230718-jajo-0600-piPredryingMass01Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.7448999999999995 g
Predrying mass 02Stacking230718-jajo-0600-piPredryingMass02Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6583000000000001 g
Predrying mass 03Stacking230718-jajo-0600-piPredryingMass03Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6117000000000008 g
Predrying mass 04Stacking230718-jajo-0600-piPredryingMass04Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6485999999999996 g
Predrying mass 05Stacking230718-jajo-0600-piPredryingMass05Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.3891 g
Predrying mass 06Stacking230718-jajo-0600-piPredryingMass06Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass
Predrying mass 07Stacking230718-jajo-0600-piPredryingMass07Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5317999999999996 g
Predrying mass 08Stacking230718-jajo-0600-piPredryingMass08Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6493 g
Predrying mass 09Stacking230718-jajo-0600-piPredryingMass09Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.46519999999999984 g
Predrying mass 10Stacking230718-jajo-0600-piPredryingMass10Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.659 g
Predrying mass 11Stacking230718-jajo-0600-piPredryingMass11Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5021 g
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage