Stacking

From KIproBatt Wiki
< 230816-gron-0100-piLabObject:OSLba741fdef2fc49038c90561616fc8eb7/S0010
m (Append data)
m (Append data)
 
(2 intermediate revisions by 2 users not shown)
Line 5: Line 5:
 
|agent=Andreas Gronbach
 
|agent=Andreas Gronbach
 
|output_objects=O0000
 
|output_objects=O0000
|start_date=2023-08-16T14:39:56.000Z
+
|start_date=2024-01-24T12:18:38.476Z
|end_date=2023-08-17T06:43:42.674Z
+
|end_date=2024-01-24T12:24:09.301Z
 
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|comment=Dummy
 
|comment=Dummy
Line 68: Line 68:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=-1.0102000000000002
 
|actual_unit=g
 
|actual_unit=g
|actual_value=-1.0102000000000002
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0102
 
|object_id=O0102
Line 82: Line 82:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=-0.6486999999999998
 
|actual_unit=g
 
|actual_unit=g
|actual_value=-0.6486999999999998
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0103
 
|object_id=O0103
Line 96: Line 96:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.5043000000000002
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.5043000000000002
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0104
 
|object_id=O0104
Line 110: Line 110:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6463000000000001
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6463000000000001
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0105
 
|object_id=O0105
Line 124: Line 124:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.5066999999999999
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.5066999999999999
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0106
 
|object_id=O0106
Line 138: Line 138:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6494999999999997
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6494999999999997
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0107
 
|object_id=O0107
Line 152: Line 152:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.5082
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.5082
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0108
 
|object_id=O0108
Line 166: Line 166:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6463000000000001
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6463000000000001
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0109
 
|object_id=O0109
Line 180: Line 180:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.5065000000000001
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.5065000000000001
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0110
 
|object_id=O0110
Line 194: Line 194:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6524999999999999
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6524999999999999
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0111
 
|object_id=O0111
Line 208: Line 208:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.502
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.502
 
 
}}
 
}}
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91

Latest revision as of 13:24, 24 January 2024


Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 230816-gron-0100-pi wurde von Andreas Gronbach bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2024-01-24T12:18:38.476Z begonnen und am 2024-01-24T12:24:09.301Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 230816-gron-0100-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0001.jpeg
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0002.jpeg
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0003.jpeg
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0004.jpeg
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0005.jpeg
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0006.jpeg
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0007.jpeg
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0008.jpeg
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0009.jpeg
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0010.jpeg
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0011.jpeg
Electrode image 12StackingElectrodeImage12Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0012.jpeg
Electrode image 13StackingElectrodeImage13Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0013.jpeg
Electrode image 14StackingElectrodeImage14Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0014.jpeg
Electrode image 15StackingElectrodeImage15Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0015.jpeg
Electrode image 16StackingElectrodeImage16Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0016.jpeg
Electrode image 17StackingElectrodeImage17Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0017.jpeg
Electrode image 18StackingElectrodeImage18Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0018.jpeg
Electrode image 19StackingElectrodeImage19Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0019.jpeg
Electrode image 20StackingElectrodeImage20Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0020.jpeg
Electrode image 21StackingElectrodeImage21Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0021.jpeg
Electrode image 22StackingElectrodeImage22Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSLba741fdef2fc49038c90561616fc8eb7S0010P0022.jpeg
Predrying mass 01Stacking230816-gron-0100-piPredryingMass01Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass-1.0102000000000002 g
Predrying mass 02Stacking230816-gron-0100-piPredryingMass02Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass-0.6486999999999998 g
Predrying mass 03Stacking230816-gron-0100-piPredryingMass03Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5043000000000002 g
Predrying mass 04Stacking230816-gron-0100-piPredryingMass04Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6463000000000001 g
Predrying mass 05Stacking230816-gron-0100-piPredryingMass05Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5066999999999999 g
Predrying mass 06Stacking230816-gron-0100-piPredryingMass06Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6494999999999997 g
Predrying mass 07Stacking230816-gron-0100-piPredryingMass07Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5082 g
Predrying mass 08Stacking230816-gron-0100-piPredryingMass08Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6463000000000001 g
Predrying mass 09Stacking230816-gron-0100-piPredryingMass09Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5065000000000001 g
Predrying mass 10Stacking230816-gron-0100-piPredryingMass10Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6524999999999999 g
Predrying mass 11Stacking230816-gron-0100-piPredryingMass11Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.502 g
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage