Electrode weighing

From KIproBatt Wiki
< 220902-joro-0700-piLabObject:OSLc3756148b21248f986a3d0bf14802665/S0020
220902-joro-0700-piElectrode weighing
m (Append data)
m (Append data)
Line 85: Line 85:
 
|nominal_unit=g
 
|nominal_unit=g
 
|actual_unit=g
 
|actual_unit=g
 +
|actual_value=0.5282
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0005
 
|object_id=O0005
Line 148: Line 149:
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|nominal_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 
|actual_type=FileType:OSL66b1f5744478411f9ef43e1832aeea01
 +
|actual_instance=OSLc3756148b21248f986a3d0bf14802665O0004.jpeg
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
}}{{OslTemplate:LabProcess/Parameter/MultiFile/File
 
|object_id=O0005
 
|object_id=O0005

Revision as of 09:58, 2 September 2022


Prozessschritt Electrode weighing

Prozessschritt Electrode weighing des Laborprozesses 220902-joro-0700-pi wurde von Jonas Rodi bearbeitet und folgt(e) auf Electrode Foil Separation bzw. lief parallel zu . Die Bearbeitung wurde am 2022-09-02T07:17:20.000Z begonnen und am 2022-09-02T07:17:20.000Z beendet.(Status: Pending <aa8d2940>)

Eingangsobjekte: 220902-joro-0700-pi.

Ausgangsobjekte: 220902-joro-0700-pi.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Dosing device <707c359d>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Category:Object) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Selected camera weighing scaleElectrode weighingCameraWeighingScaleParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Satorius Cam Weighing Scale
CamScale 1 (TKIII 004)
Electrode image 1Electrode weighingElectrode1ElectrodeImage1Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLc3756148b21248f986a3d0bf14802665O0001.jpeg|frameless|border|text-top|
Electrode image 2Electrode weighingElectrode1ElectrodeImage2Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLc3756148b21248f986a3d0bf14802665O0002.jpeg|frameless|border|text-top|
Electrode image 3Electrode weighingElectrode1ElectrodeImage3Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLc3756148b21248f986a3d0bf14802665O0003.jpeg|frameless|border|text-top|
Electrode image 4Electrode weighingElectrode1ElectrodeImage4Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLc3756148b21248f986a3d0bf14802665O0004.jpeg|frameless|border|text-top|
Electrode image 5Electrode weighingElectrode1ElectrodeImage5Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSLc3756148b21248f986a3d0bf14802665O0005.jpeg|frameless|border|text-top|
Predrying mass 1Electrode weighingElectrode1PredryingMass1Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5188 g
Predrying mass 2Electrode weighingElectrode1PredryingMass2Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5235 g
Predrying mass 3Electrode weighingElectrode1PredryingMass3Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5258 g
Predrying mass 4Electrode weighingElectrode1PredryingMass4Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5282 g
Predrying mass 5Electrode weighingElectrode1PredryingMass5Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5181 g

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage