Stacking

From KIproBatt Wiki
< 230911-gron-0600-piLabObject:OSL58691e9b10b0484d8faad500b1560778/S0010
(Created page with "{{OslTemplate:LabProcess/Step/Subpage |name=Stacking |process=LabObject:OSL58691e9b10b0484d8faad500b1560778 |predecessor=LabObject:OSL58691e9b10b0484d8faad500b1560778/S0000 |a...")
 
m (Append data)
Line 5: Line 5:
 
|agent=Andreas Gronbach
 
|agent=Andreas Gronbach
 
|output_objects=O0000
 
|output_objects=O0000
|start_date=2023-09-28T07:24:26.000Z
+
|start_date=2023-09-28T07:54:25.781Z
 
|end_date=2023-09-28T07:24:26.000Z
 
|end_date=2023-09-28T07:24:26.000Z
 
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512
 
|status=Term:OSLaa8d29404288446a9f3ec7afa4e2a512

Revision as of 08:54, 28 September 2023


Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 230911-gron-0600-pi wurde von Andreas Gronbach bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2023-09-28T07:54:25.781Z begonnen und am 2023-09-28T07:24:26.000Z beendet.(Status: Pending <aa8d2940>)

Eingangsobjekte: .

Ausgangsobjekte: 230911-gron-0600-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0001.jpeg
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0002.jpeg
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0003.jpeg
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0004.jpeg
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0005.jpeg
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0006.jpeg
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0007.jpeg
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0008.jpeg
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0009.jpeg|frameless|border|text-top|
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0010.jpeg
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0011.jpeg
Electrode image 12StackingElectrodeImage12Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0012.jpeg
Electrode image 13StackingElectrodeImage13Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0013.jpeg
Electrode image 14StackingElectrodeImage14Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0014.jpeg
Electrode image 15StackingElectrodeImage15Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0015.jpeg
Electrode image 16StackingElectrodeImage16Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0016.jpeg
Electrode image 17StackingElectrodeImage17Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0017.jpeg
Electrode image 18StackingElectrodeImage18Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0018.jpeg
Electrode image 19StackingElectrodeImage19Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0019.jpeg
Electrode image 20StackingElectrodeImage20Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0020.jpeg
Electrode image 21StackingElectrodeImage21Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0021.jpeg
Electrode image 22StackingElectrodeImage22Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL58691e9b10b0484d8faad500b1560778S0010P0022.jpeg
Predrying mass 01Stacking230911-gron-0600-piPredryingMass01Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5045999999999999 g
Predrying mass 02Stacking230911-gron-0600-piPredryingMass02Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass2.1670999999999996 g
Predrying mass 03Stacking230911-gron-0600-piPredryingMass03Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5063000000000004 g
Predrying mass 04Stacking230911-gron-0600-piPredryingMass04Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass-2.165899999999999 g
Predrying mass 05Stacking230911-gron-0600-piPredryingMass05Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5057 g
Predrying mass 06Stacking230911-gron-0600-piPredryingMass06Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.16949999999999932 g
Predrying mass 07Stacking230911-gron-0600-piPredryingMass07Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5030999999999994 g
Predrying mass 08Stacking230911-gron-0600-piPredryingMass08Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass-0.5146999999999995 g
Predrying mass 09Stacking230911-gron-0600-piPredryingMass09Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5051000000000001 g
Predrying mass 10Stacking230911-gron-0600-piPredryingMass10Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass-1.7979000000000003 g
Predrying mass 11Stacking230911-gron-0600-piPredryingMass11Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.5049999999999999 g
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage