Electrode weighing

From KIproBatt Wiki
< 220628-gron-0600-piLabObject:OSL76685e798ba44431b6c2330d10125257/S0020 /
Revision as of 09:58, 28 June 2022 by Andreas Gronbach (talk | contribs) (Created page with "{{OslTemplate:LabProcess/Step/Subpage |name=Electrode weighing |process=LabObject:OSL76685e798ba44431b6c2330d10125257 |predecessor=LabObject:OSL76685e798ba44431b6c2330d1012525...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
220628-gron-0600-piElectrode weighing


Prozessschritt Electrode weighing

Prozessschritt Electrode weighing des Laborprozesses 220628-gron-0600-pi wurde von Andreas Gronbach bearbeitet und folgt(e) auf LabObject:OSL76685e798ba44431b6c2330d10125257/S0010 bzw. lief parallel zu . Die Bearbeitung wurde am 2022-06-28T08:57:50.000Z begonnen und am 2022-06-28T08:57:50.000Z beendet.(Status: Pending <aa8d2940>)

Eingangsobjekte: 220628-gron-0600-pi.

Ausgangsobjekte: 220628-gron-0600-pi.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Dosing device <707c359d>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Category:Object) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Selected camera weighing scaleElectrode weighingCameraWeighingScaleParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Satorius Cam Weighing Scale
CamScale 1 (TKIII 004)
Electrode image 1Electrode weighingElectrode1ElectrodeImage1Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL76685e798ba44431b6c2330d10125257O0001.jpeg
Electrode image 2Electrode weighingElectrode1ElectrodeImage2Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL76685e798ba44431b6c2330d10125257O0002.jpeg
Electrode image 3Electrode weighingElectrode1ElectrodeImage3Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL76685e798ba44431b6c2330d10125257O0003.jpeg
Electrode image 4Electrode weighingElectrode1ElectrodeImage4Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL76685e798ba44431b6c2330d10125257O0004.jpeg
Electrode image 5Electrode weighingElectrode1ElectrodeImage5Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL76685e798ba44431b6c2330d10125257O0005.jpeg
Electrode image 6Electrode weighingElectrode1ElectrodeImage6Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFile
Predrying mass 1Electrode weighingElectrode1PredryingMass1Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6415 g
Predrying mass 2Electrode weighingElectrode1PredryingMass2Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6406 g
Predrying mass 3Electrode weighingElectrode1PredryingMass3Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6373 g
Predrying mass 4Electrode weighingElectrode1PredryingMass4Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6397 g
Predrying mass 5Electrode weighingElectrode1PredryingMass5Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6368 g
Predrying mass 6Electrode weighingElectrode1PredryingMass6Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage