Electrode weighing

< 220926-sist-0100-piLabObject:OSL062c677e028b42439b2fc092e3e84669/S0020 /
Revision as of 13:09, 15 November 2022 by Iot-bot (talk | contribs) (Append data)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
220926-sist-0100-piElectrode weighing


Prozessschritt Electrode weighing

Prozessschritt Electrode weighing des Laborprozesses 220926-sist-0100-pi wurde von Simon Stier bearbeitet und folgt(e) auf LabObject:OSL062c677e028b42439b2fc092e3e84669/S0010 bzw. lief parallel zu . Die Bearbeitung wurde am 2022-09-26T14:16:57.000Z begonnen und am 2022-11-15T12:09:23.452Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: 220926-sist-0100-pi.

Ausgangsobjekte: 220926-sist-0100-pi.


Generischer Prozessschritt vom Typ -nicht festgelegt-.




Prozessparameter

 ProzessObjektNameTypAttributWert
Selected camera weighing scaleElectrode weighingCameraWeighingScaleParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Satorius Cam Weighing Scale
CamScale 1 (TKIII 004)
Electrode image 1Electrode weighingElectrode1ElectrodeImage1Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFileOSL062c677e028b42439b2fc092e3e84669O0001.jpeg|frameless|border|text-top|
Electrode image 2Electrode weighingElectrode1ElectrodeImage2Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFile
Electrode image 3Electrode weighingElectrode1ElectrodeImage3Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFile
Electrode image 4Electrode weighingElectrode1ElectrodeImage4Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFile
Electrode image 5Electrode weighingElectrode1ElectrodeImage5Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFile
Electrode image 6Electrode weighingElectrode1ElectrodeImage6Parameter/Actual
Parameter/File
Fabricated electrode frontside image
HasFile
Predrying mass 1Electrode weighingElectrode1PredryingMass1Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 2Electrode weighingElectrode1PredryingMass2Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass
Predrying mass 3Electrode weighingElectrode1PredryingMass3Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass
Predrying mass 4Electrode weighingElectrode1PredryingMass4Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass
Predrying mass 5Electrode weighingElectrode1PredryingMass5Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass
Predrying mass 6Electrode weighingElectrode1PredryingMass6Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage