220628-gron-2200-pi

From KIproBatt Wiki
LabObject:OSL3132ab00455d459e9884e6425cc042ec /
Revision as of 09:27, 23 August 2022 by Simon Stier (talk | contribs) (set KIproBatt as default project)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)



ID 220628-gron-2200-pi
Ersteller Andreas Gronbach
Vorlage KIproBatt v1 Separation
Produkt- / Ergebniskategorie Elektrodenmagazin <b1415173>
Produkt- / Ergebnis Anode magazine (KIproBatt v2) <5cf05450>
Projekt KIproBatt
Erstelldatum 28.06.2022 11:07:45
Beschreibung Gut-Zellen

Vorschrift

Electrode Foil Selection

O0090;

Generischer Prozessschritt

Parameter

Electrode Foil Separation

O0001;O0002;O0003;O0004;O0005;O0006;

Generischer Prozessschritt

Parameter

Electrode weighing

(Details)

O0000;

Generischer Prozessschritt

Parameter

 ObjektNameWert
Selected camera weighing scaleCameraWeighingScaleSatorius Cam Weighing Scale
CamScale 1 (TKIII 004)
Electrode image 1Electrode1ElectrodeImage1OSL3132ab00455d459e9884e6425cc042ecO0001.jpeg
Electrode image 2Electrode1ElectrodeImage2OSL3132ab00455d459e9884e6425cc042ecO0002.jpeg
Electrode image 3Electrode1ElectrodeImage3OSL3132ab00455d459e9884e6425cc042ecO0003.jpeg
Electrode image 4Electrode1ElectrodeImage4OSL3132ab00455d459e9884e6425cc042ecO0004.jpeg
Electrode image 5Electrode1ElectrodeImage5OSL3132ab00455d459e9884e6425cc042ecO0005.jpeg
Electrode image 6Electrode1ElectrodeImage6OSL3132ab00455d459e9884e6425cc042ecO0006.jpeg
Predrying mass 1Electrode1PredryingMass10.5073 g
Predrying mass 2Electrode1PredryingMass20.5037 g
Predrying mass 3Electrode1PredryingMass30.5092 g
Predrying mass 4Electrode1PredryingMass40.5053 g
Predrying mass 5Electrode1PredryingMass50.5054 g
Predrying mass 6Electrode1PredryingMass60.5081 g



Produkte

IDTyp
220628-gron-2200-miAnode magazine (KIproBatt v2)

Weitere Verwendung

 DatumVorschriftErsteller
220628-gron-2500-pi28 June 2022 16:21:51KIproBatt v1 DryingAndreas Gronbach

Data Graph