221020-joro-0100-pi

From KIproBatt Wiki
LabObject:OSL7f8f33fda03942a6b2bdf7e02bc1088a /
Revision as of 08:14, 20 October 2022 by Jon90851 (talk | contribs) (Created page with "{{OslTemplate:LabProcess/Instance |id=221020-joro-0100-pi |short_timestamp=221020 |creator_abbreviation=joro |type_symbol=pi |template=LabProcess:OSLbc089261bd1b470c9ec5e159ce...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)



ID 221020-joro-0100-pi
Ersteller Jonas Rodi
Vorlage KIproBatt v1 Filling
Produkt- / Ergebniskategorie Filled cell <d83db70a>
Produkt- / Ergebnis Filled cell (KIproBatt v1) <be31a19a>
Projekt KIproBatt
Erstelldatum 20.10.2022 08:14:22
Beschreibung US-Messung

Vorschrift

Cell Count Determination

(Details)

Generischer Prozessschritt

Parameter

 ObjektNameWert
Cell countCellCount1



Filling

(Details)

O0001;

Generischer Prozessschritt

Parameter

 ObjektNameWert
Cell selection 1221020-joro-0101-miCellSelection1221012-joro-0500-mi
Dry cell with bracing mass 1221020-joro-0101-miDryCellWithBracingMass112.3263 g
Electrolyte flushing volumeElectrolyteFlushingVolume15 ml
Electrolyte selectionElectrolyteSelection
Electrolyte volume 1221020-joro-0101-miElectrolyteVolume12.1 ml
Filling device selectionFillingDeviceSelectionHarro Höflinger XX
Harro Höflinger XX (TKIII 004)
Glovebox device selectionGloveboxDeviceSelectionGS Glovebox
LIB-Box
Injection pressureInjectionPressure100 mbar
Sealing pressureSealingPressure50 mbar
Solvent flushing volumeSolventFlushingVolume15 ml
Wett cell mass 1221020-joro-0101-miWettCellMass114.0185 g



Produkte

IDTyp
221020-joro-0101-miFilled cell (KIproBatt v1)

Weitere Verwendung

Data Graph