Formation and EoL-Test

From KIproBatt Wiki
< 221124-joro-0300-piLabObject:OSL70d9cf6830fb4a849ce2cdcfc725f1df/S0010 /
Revision as of 14:16, 24 November 2022 by Jon90851 (talk | contribs) (Created page with "{{OslTemplate:LabProcess/Step/Subpage |name=Formation and EoL-Test |process=LabObject:OSL70d9cf6830fb4a849ce2cdcfc725f1df |predecessor=LabObject:OSL70d9cf6830fb4a849ce2cdcfc72...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
221124-joro-0300-piFormation and EoL-Test


Prozessschritt Formation and EoL-Test

Prozessschritt Formation and EoL-Test des Laborprozesses 221124-joro-0300-pi wurde von Jonas Rodi bearbeitet und folgt(e) auf Cell Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2022-11-24T13:14:27.000Z begonnen und am 2022-11-24T13:14:28.000Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 221124-joro-0300-pi.

Die Vorbedingung Brace cells wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Battery tester <aae2538b>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriezelle <a8f80efb>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Battery tester selectionFormation and EoL-TestBatteryTesterSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Maccor Series 4000
Maccor#2
Compacting pressure 1Formation and EoL-Test221124-joro-0301-miCompactingPressure1Parameter/Actual
Parameter/Quantitative
CompactingPressure
Pressure
Compacting pressure 2Formation and EoL-Test221124-joro-0302-miCompactingPressure2Parameter/Actual
Parameter/Quantitative
CompactingPressure
Pressure
Compacting pressure 3Formation and EoL-Test221124-joro-0303-miCompactingPressure3Parameter/Actual
Parameter/Quantitative
CompactingPressure
Pressure
Compacting pressure 4Formation and EoL-Test221124-joro-0304-miCompactingPressure4Parameter/Actual
Parameter/Quantitative
CompactingPressure
Pressure
CSV export fileFormation and EoL-Test221124-joro-0300-miCsvExportFileParameter/Actual
Parameter/File
HasFile
CSV export file cell 1Formation and EoL-Test221124-joro-0301-miCsvExportFileCell1Parameter/Actual
Parameter/File
HasFile
CSV export file cell 2Formation and EoL-Test221124-joro-0302-miCsvExportFileCell2Parameter/Actual
Parameter/File
HasFile
CSV export file cell 3Formation and EoL-Test221124-joro-0303-miCsvExportFileCell3Parameter/Actual
Parameter/File
HasFile
CSV export file cell 4Formation and EoL-Test221124-joro-0304-miCsvExportFileCell4Parameter/Actual
Parameter/File
HasFile
Formation cell selection 1Formation and EoL-Test221124-joro-0301-miFormationCellSelection1Parameter/Actual
Parameter/InputObject
HasPredecessor221124-joro-0102-mi
Formation cell selection 2Formation and EoL-Test221124-joro-0302-miFormationCellSelection2Parameter/Actual
Parameter/InputObject
HasPredecessor221124-joro-0106-mi
Formation cell selection 3Formation and EoL-Test221124-joro-0303-miFormationCellSelection3Parameter/Actual
Parameter/InputObject
HasPredecessor221124-joro-0110-mi
Formation cell selection 4Formation and EoL-Test221124-joro-0304-miFormationCellSelection4Parameter/Actual
Parameter/InputObject
HasPredecessor221124-joro-0114-mi
Formation temperatureFormation and EoL-TestFormationTemperatureParameter/Actual
Parameter/Quantitative
FormationTemperature
Temperature25 °C
HDF4 export fileFormation and EoL-Test221124-joro-0300-miHdf4ExportFileParameter/Actual
Parameter/File
HasFile
Measurement channel 1Formation and EoL-Test221124-joro-0301-miMeasurementChannel1Parameter/Actual
Parameter/Quantitative
MeasurementChannel
Number61
Measurement channel 2Formation and EoL-Test221124-joro-0302-miMeasurementChannel2Parameter/Actual
Parameter/Quantitative
MeasurementChannel
Number62
Measurement channel 3Formation and EoL-Test221124-joro-0303-miMeasurementChannel3Parameter/Actual
Parameter/Quantitative
MeasurementChannel
Number63
Measurement channel 4Formation and EoL-Test221124-joro-0304-miMeasurementChannel4Parameter/Actual
Parameter/Quantitative
MeasurementChannel
Number64
Raw data export fileFormation and EoL-Test221124-joro-0300-miRawDataExportFileParameter/Actual
Parameter/File
HasFile
Testing cell selection 1Formation and EoL-Test221124-joro-0351-miTestingCellSelection1Parameter/Actual
Parameter/InputObject
HasPredecessor
Testing cell selection 2Formation and EoL-Test221124-joro-0352-miTestingCellSelection2Parameter/Actual
Parameter/InputObject
HasPredecessor
Testing cell selection 3Formation and EoL-Test221124-joro-0353-miTestingCellSelection3Parameter/Actual
Parameter/InputObject
HasPredecessor
Testing cell selection 4Formation and EoL-Test221124-joro-0354-miTestingCellSelection4Parameter/Actual
Parameter/InputObject
HasPredecessor

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage