221024-joro-0100-pi

LabObject:OSLd70d4a0ad79d4669b31a9ee21ffcc27e /
Revision as of 14:15, 1 December 2022 by Jon90851 (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)



ID 221024-joro-0100-pi
Ersteller Jonas Rodi
Vorlage KIproBatt v1 Filling
Produkt- / Ergebniskategorie Filled cell <d83db70a>
Produkt- / Ergebnis Filled cell (KIproBatt v1) <be31a19a>
Projekt KIproBatt
Erstelldatum 24.10.2022 12:01:13
Beschreibung US-Messung

Vorschrift

Cell Count Determination

(Details)

Generischer Prozessschritt

Parameter

 ObjektNameWert
Cell countCellCount2



Filling

(Details)

O0001;O0002;

Generischer Prozessschritt

Parameter

 ObjektNameWert
Cell selection 1221024-joro-0101-miCellSelection1221012-joro-0300-mi
Cell selection 2221024-joro-0102-miCellSelection2221012-joro-0400-mi
Dry cell with bracing mass 1221024-joro-0101-miDryCellWithBracingMass112.496 g
Dry cell with bracing mass 2221024-joro-0102-miDryCellWithBracingMass212.5518 g
Electrolyte flushing volumeElectrolyteFlushingVolume15 ml
Electrolyte selectionElectrolyteSelection
Electrolyte volume 1221024-joro-0101-miElectrolyteVolume11.1 ml
Electrolyte volume 2221024-joro-0102-miElectrolyteVolume21.1 ml
Filling device selectionFillingDeviceSelectionHarro Höflinger XX
Harro Höflinger XX (TKIII 004)
Glovebox device selectionGloveboxDeviceSelectionGS Glovebox
LIB-Box
Injection pressureInjectionPressure100 mbar
Sealing pressureSealingPressure50 mbar
Solvent flushing volumeSolventFlushingVolume15 ml
Wett cell mass 1221024-joro-0101-miWettCellMass114.0134 g
Wett cell mass 2221024-joro-0102-miWettCellMass214.1396 g



Produkte

IDTyp
221024-joro-0101-miFilled cell (KIproBatt v1)
221024-joro-0102-miFilled cell (KIproBatt v1)

Weitere Verwendung

Data Graph