Filling

< 220626-sist-0100-piLabObject:OSL359d6c0d54bf466fbceb96f5fdf21385/S0010 /
Revision as of 14:04, 26 June 2022 by Simon Stier (talk | contribs) (Created page with "{{OslTemplate:LabProcess/Step/Subpage |name=Filling |process=LabObject:OSL359d6c0d54bf466fbceb96f5fdf21385 |predecessor=LabObject:OSL359d6c0d54bf466fbceb96f5fdf21385/S0000 |ag...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)


Prozessschritt Filling

Prozessschritt Filling des Laborprozesses 220626-sist-0100-pi wurde von Simon Stier bearbeitet und folgt(e) auf Cell Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2022-06-26T13:03:33.000Z begonnen und am 2022-06-26T13:03:33.000Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 220626-sist-0100-pi.


Generischer Prozessschritt vom Typ -nicht festgelegt-.




Prozessparameter

 ProzessObjektNameTypAttributWert
Cell selection 1Filling220626-sist-0101-miCellSelection1Parameter/Actual
Parameter/InputObject
HasPredecessor220623-sist-0300-mi
Dry cell with bracing mass 1Filling220626-sist-0101-miDryCellWithBracingMass1Parameter/Actual
Parameter/Quantitative
DryCellWithBracingMass
Mass5 g
Electrolyte flushing volumeFillingElectrolyteFlushingVolumeParameter/Actual
Parameter/Quantitative
Volume15 ml
Electrolyte selectionFillingElectrolyteSelectionParameter/Actual
Parameter/InputObject
HasPredecessorElyte EC/DMC 3:7 + 2% VC Flasche 1
Electrolyte volume 1Filling220626-sist-0101-miElectrolyteVolume1Parameter/Actual
Parameter/Quantitative
ElectrolyteVolume
Volume2.1 ml
Filling device selectionFillingFillingDeviceSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Harro Höflinger XX
Harro Höflinger XX (TKIII 004)
Glovebox device selectionFillingGloveboxDeviceSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
GS Glovebox
LIB-Box
Injection pressureFillingInjectionPressureParameter/Actual
Parameter/Quantitative
Pressure100 mbar
Sealing pressureFillingSealingPressureParameter/Actual
Parameter/Quantitative
Pressure50 mbar
Solvent flushing volumeFillingSolventFlushingVolumeParameter/Actual
Parameter/Quantitative
Volume15 ml
Wett cell mass 1Filling220626-sist-0101-miWettCellMass1Parameter/Actual
Parameter/Quantitative
WettCellMass
Mass7.1 g

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage