Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 220919-joro-1300-pi wurde von Jonas Rodi bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2022-09-19T13:10:27.000Z begonnen und am 2022-09-19T13:10:27.000Z beendet.(Status: Pending <aa8d2940>)

Eingangsobjekte: .

Ausgangsobjekte: 220919-joro-1300-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor220919-joro-0112-mi
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor220919-joro-0124-mi
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFile
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessorCG2 (CG2320)
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage