EoL test/Nominal capacity

From KIproBatt Wiki
< Fraunhofer ISC‎ | Processes‎ | KIproBatt v1Fraunhofer ISC/Processes/KIproBatt v1/Parameter/EoL test/Nominal capacity
EoL testEoL test/Nominal capacity


Description

Semantic Links

Add or edit outgoing links
To edit incoming links, go to the subjects site.

Outgoing

Incoming

Semantic Statements

Add statement

Statement Subject Property Object Reference Statement Quality
000000017 Filling/Degree of wetting Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Undefined direct correlation
Has priority High
000000035 Formation/SEI Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Undefined direct correlation
Has priority High
100000966 Separation/Specific mass loading Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000967 Separation/Thickness Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000968 Separation/Porosity Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000969 Separation/Appearance Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000970 Separation/Coating edge Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000971 Separation/Defects Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000972 Drying/Temperature Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000973 Drying/Duration Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000974 Drying/Pressure Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000975 Drying/Residual humidity Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has priority High
Has correlation type Defined direct correlation
100000977 Stacking/Appearance Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000978 Stacking/Coating edge Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000979 Stacking/Defects Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has priority High
Has correlation type Defined direct correlation
100000980 Stacking/Weight Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000981 Stacking/Stacking accuracy Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000982 Stacking/Ambient conditions Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Undefined direct correlation
100000983 Filling/Electrolyte quantity Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000984 Filling/Pressure Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000985 Filling/Temperature Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000986 Filling/Wetting time Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000987 Formation/Procedure Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
Has priority High
100000988 Formation/Cell bracing Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000989 Formation/Temperature Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
100000990 Formation/OCV Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
Has priority High
100000991 Formation/Cell temperature Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has priority High
Has correlation type Defined direct correlation
100000994 Formation/Consumed energy Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
Has priority High
100000995 Formation/Capacity Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has priority High
Has correlation type Defined direct correlation
100000996 Formation/Impedance Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Indirect correlation
Has priority High
100000997 Degassing/Gas volume Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has priority High
Has correlation type Defined direct correlation
100000998 Degassing/Pressure at sealing Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100000999 Aging/Procedure Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001000 Aging/Cell bracing pressure Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001001 Aging/Cell temperature Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001002 Aging/Volume change Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001003 Aging/Coulombic efficiency Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001004 Aging/Consumed energy Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001005 Aging/Capacity development Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001006 Aging/Impedance Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001009 EoL test/Voltage Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001010 EoL test/Nominal capacity Has correlation to EoL test/Nominal capacity Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001059 EoL test/Nominal capacity Has correlation to EoL test/Impedance Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001109 EoL test/Nominal capacity Has correlation to Cyclization/Capacity development Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation
100001159 EoL test/Nominal capacity Has correlation to Cyclization/Performance test Wirkmatrix.V5 Assumption
Has correlation type Defined direct correlation

External Identifiers

IRI:




Direct Correlations