5,582 bytes added
, 10:01, 30 September 2022
{{OslTemplate:LabProcess/Step/Subpage
|name=Filling
|process=LabObject:OSL61e1f4efcf394c7fb0eaea16640c762f
|predecessor=LabObject:OSL61e1f4efcf394c7fb0eaea16640c762f/S0000
|agent=Jon90851
|output_objects=O0001
|start_date=2022-09-30T08:53:07.000Z
|end_date=2022-09-30T08:53:07.000Z
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
|precondition_fulfilled=No
|postcondition_fulfilled=No
}}
{{OslTemplate:LabProcess/Steps/Generic/Subpage
|nominal_tool_category=OSL707c359d5b3d43e480458bc0da142359
|actual_tool_category=OSL707c359d5b3d43e480458bc0da142359
|tools={{OslTemplate:LabProcess/Parameter/MultiTool/Tool
|name=FillingDeviceSelection
|label=Filling device selection
|id=P0100
|nominal_category=Category:OSL707c359d5b3d43e480458bc0da142359
|actual_category=Category:OSL707c359d5b3d43e480458bc0da142359
|actual_category_sync_active=No
|nominal_type=Device:OSL8f44538e3f1247b3a40422054c664a14
|actual_type=Device:OSL8f44538e3f1247b3a40422054c664a14
|nominal_instance=LabObject:OSLf7e62edcf0e64084a0d92ff0f7a9efe8
|actual_instance=LabObject:OSLf7e62edcf0e64084a0d92ff0f7a9efe8
}}{{OslTemplate:LabProcess/Parameter/MultiTool/Tool
|name=GloveboxDeviceSelection
|label=Glovebox device selection
|id=P0101
|nominal_category=Category:OSLa88e409a039f4e81bd8a1fa4c7f14295
|actual_category=Category:OSLa88e409a039f4e81bd8a1fa4c7f14295
|actual_category_sync_active=No
|nominal_type=Device:OSL795f8130ffd24daaaff613db085740e6
|actual_type=Device:OSL795f8130ffd24daaaff613db085740e6
|nominal_instance=LabObject:OSLdd97bab91f6541f78bd441aae6412c28
|actual_instance=LabObject:OSLdd97bab91f6541f78bd441aae6412c28
}}
|nominal_object_category=Material
|actual_object_category=Material
|objects={{OslTemplate:LabProcess/Parameter/MultiObject/Object
|name=ElectrolyteSelection
|label=Electrolyte selection
|id=P0000
|nominal_category=Category:OSL0cdd7b45aa6a47fdbf8ca9e7ddc06531
|actual_category=Category:OSL0cdd7b45aa6a47fdbf8ca9e7ddc06531
|actual_category_sync_active=No
|nominal_type=Material:OSL76643ae2095740d787b9cc7f14938502
|actual_type=Material:OSL76643ae2095740d787b9cc7f14938502
|nominal_instance=LabObject:OSLa64368d137e7432e9ebab5ad05cff30b
|actual_instance=LabObject:OSLa64368d137e7432e9ebab5ad05cff30b
}}{{OslTemplate:LabProcess/Parameter/MultiObject/Object
|object_id=O0001
|name=CellSelection1
|label=Cell selection 1
|id=P0001
|nominal_category=Category:OSLf034e81cd50d4e9ba8e9e31215d39ff0
|actual_category=Category:OSLf034e81cd50d4e9ba8e9e31215d39ff0
|actual_category_sync_active=No
|actual_type=Material:OSLe8c5465c93e64e5989b51ac0552529f2
|actual_instance=LabObject:OSLa48cf9d239454143a14172bbebac2428#O0002
}}
|nominal_quantitative_category=Property
|actual_quantitative_category=Property
|quantitatives={{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=SolventFlushingVolume
|label=Solvent flushing volume
|id=P0111
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasVolume
|actual_quantity=Property:HasVolume
|nominal_value=15
|nominal_unit=ml
|actual_value=15
|actual_unit=ml
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=ElectrolyteFlushingVolume
|label=Electrolyte flushing volume
|id=P0112
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasVolume
|actual_quantity=Property:HasVolume
|nominal_value=15
|nominal_unit=ml
|actual_value=15
|actual_unit=ml
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=InjectionPressure
|label=Injection pressure
|id=P0113
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasPressure
|actual_quantity=Property:HasPressure
|nominal_value=100
|nominal_unit=mbar
|actual_value=100
|actual_unit=mbar
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=SealingPressure
|label=Sealing pressure
|id=P0114
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasPressure
|actual_quantity=Property:HasPressure
|nominal_value=50
|nominal_unit=mbar
|actual_value=50
|actual_unit=mbar
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|object_id=O0001
|type=Term:DryCellWithBracingMass
|name=DryCellWithBracingMass1
|label=Dry cell with bracing mass 1
|id=P0201
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasMass
|actual_quantity=Property:HasMass
|nominal_unit=g
|actual_value=11.8386
|actual_unit=g
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|object_id=O0001
|type=Term:ElectrolyteVolume
|name=ElectrolyteVolume1
|label=Electrolyte volume 1
|id=P0301
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasVolume
|actual_quantity=Property:HasVolume
|nominal_value=2.1
|nominal_unit=ml
|actual_value=1.1
|actual_unit=ml
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|object_id=O0001
|type=Term:WettCellMass
|name=WettCellMass1
|label=Wett cell mass 1
|id=P0401
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasMass
|actual_quantity=Property:HasMass
|nominal_unit=g
|actual_value=13.536
|actual_unit=g
}}
}}