{{OslTemplate:LabProcess/Step/Subpage
|name=Drying
|process=LabObject:OSL66cea54bbca74ef48ca595490051bae8
|predecessor=LabObject:OSL66cea54bbca74ef48ca595490051bae8/S0000
|agent=Simon Stier
|output_objects=O0001
|start_date=2022-06-23T10:00:32.000Z
|end_date=2022-06-23T10:00:32.000Z
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
|precondition_fulfilled=No
|postcondition=Check correct start and end time!
|postcondition_fulfilled=No
}}
{{OslTemplate:LabProcess/Steps/Generic/Subpage
|actual_tool_category=OSLefbb17cf2ca24aba9390027ea09bae79
|tools={{OslTemplate:LabProcess/Parameter/MultiTool/Tool
|name=DryingDeviceSelection
|label=Device selection
|id=P0000
|nominal_category=Category:OSLefbb17cf2ca24aba9390027ea09bae79
|actual_category=Category:OSLefbb17cf2ca24aba9390027ea09bae79
|actual_category_sync_active=Yes
|nominal_type=Device:OSLbaaf7f88142d4b8d91d5ae3df71acb7c
|actual_type=Device:OSLbaaf7f88142d4b8d91d5ae3df71acb7c
|actual_instance=LabObject:OSL1ccce9c3c7e6477a817ab4d1e3f84b67
}}
|actual_object_category=OSLb1415173552d4921acf30ac51f3bce62
|objects={{OslTemplate:LabProcess/Parameter/MultiObject/Object
|object_id=O0001
|name=MagazineSelection1
|label=Magazine selection 1
|id=P0001
|nominal_category=Category:OSLb1415173552d4921acf30ac51f3bce62
|actual_category=Category:OSLb1415173552d4921acf30ac51f3bce62
|actual_category_sync_active=Yes
|actual_type=Material:OSLa6b343604e5f4022a4a9feeef0f6adc6
|actual_instance=LabObject:OSLdf6fce3dc9ef439b88731a1dcd62c6eb#O0000
}}{{OslTemplate:LabProcess/Parameter/MultiObject/Object
|object_id=O0002
|name=MagazineSelection2
|label=Magazine selection 2
|id=P0002
|nominal_category=Category:OSLb1415173552d4921acf30ac51f3bce62
|actual_category=Category:OSLb1415173552d4921acf30ac51f3bce62
|actual_category_sync_active=Yes
|actual_type=Material:OSL5cf054503ea24a1eafddf18250cb6dfa
|actual_instance=LabObject:OSLc920ceb7444b44bdb369fbde35f82d77#O0000
}}
|actual_quantitative_category=Property
|quantitatives={{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|type=Fraunhofer_ISC/Processes/KIproBatt_v1/Parameter/Drying/Temperature
|name=Temperature
|label=Quantitative 0
|id=P0101
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasTemperature
|actual_quantity=Property:HasTemperature
|nominal_value=110
|nominal_unit=°C
|actual_value=110
|actual_unit=°C
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=Duration
|label=Quantitative 0
|id=P0102
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasDuration
|actual_quantity=Property:HasDuration
|nominal_value=12
|nominal_unit=h
|actual_value=12
|actual_unit=h
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=Pressure
|label=Quantitative 0
|id=P0103
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasPressure
|actual_quantity=Property:HasPressure
|nominal_value=50
|nominal_unit=mbar
|actual_value=50
|actual_unit=mbar
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=NumberOfVentilations
|label=Number of ventilations
|id=P0104
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasNumberOfEntities
|actual_quantity=Property:HasNumberOfEntities
|nominal_value=5
|actual_value=5
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
|name=VentilationPressure
|label=Ventilation pressure
|id=P0105
|nominal_category=Category:QuantityProperty
|actual_category=Category:QuantityProperty
|actual_category_sync_active=No
|nominal_quantity=Property:HasPressure
|actual_quantity=Property:HasPressure
|nominal_value=500
|nominal_unit=mbar
|actual_value=500
|actual_unit=mbar
}}
|actual_file_category=File
}}