Stacking

From KIproBatt Wiki
< 230504-jajo-1500-piLabObject:OSL613be11b4c9847ea98c41ca412d01e32/S0010
m (Append data)
 
Line 5: Line 5:
 
|agent=Jannis Johann
 
|agent=Jannis Johann
 
|output_objects=O0000
 
|output_objects=O0000
|start_date=2023-05-05T13:19:25.513Z
+
|start_date=2023-05-05T13:19:25.000Z
|end_date=2023-05-05T13:30:34.225Z
+
|end_date=2023-05-05T13:30:34.000Z
 
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
 
|status=Term:OSLf474ec34b7df451ea8356134241aef8a
|comment=wetting analysis batch 1
+
|comment=Position Ableitertabs (Referenz)
 
|precondition=Check PLC Setting Camera on, correct electrode count
 
|precondition=Check PLC Setting Camera on, correct electrode count
 
|precondition_fulfilled=No
 
|precondition_fulfilled=No
Line 72: Line 72:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0102
 
|object_id=O0102
Line 86: Line 86:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6430999999999996
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6430999999999996
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0103
 
|object_id=O0103
Line 113: Line 113:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6421000000000001
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6421000000000001
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0105
 
|object_id=O0105
Line 127: Line 127:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0106
 
|object_id=O0106
Line 141: Line 141:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6438999999999999
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6438999999999999
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0107
 
|object_id=O0107
Line 155: Line 155:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0108
 
|object_id=O0108
Line 169: Line 169:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6486000000000001
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6486000000000001
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0109
 
|object_id=O0109
Line 183: Line 183:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0110
 
|object_id=O0110
Line 197: Line 197:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0.6520000000000001
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0.6520000000000001
 
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
}}{{OslTemplate:LabProcess/Parameter/MultiQuantitative/Quantitative
 
|object_id=O0111
 
|object_id=O0111
Line 211: Line 211:
 
|actual_quantity=Property:HasMass
 
|actual_quantity=Property:HasMass
 
|nominal_unit=g
 
|nominal_unit=g
 +
|actual_value=0
 
|actual_unit=g
 
|actual_unit=g
|actual_value=0
 
 
}}
 
}}
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91
 
|nominal_file_category=OSLf3e9655d44bd404493e765bd1fe62c91

Latest revision as of 16:10, 5 May 2023


Prozessschritt Stacking

Prozessschritt Stacking des Laborprozesses 230504-jajo-1500-pi wurde von Jannis Johann bearbeitet und folgt(e) auf Electrode Count Determination bzw. lief parallel zu . Die Bearbeitung wurde am 2023-05-05T13:19:25.000Z begonnen und am 2023-05-05T13:30:34.000Z beendet.(Status: Done <f474ec34>)

Eingangsobjekte: .

Ausgangsobjekte: 230504-jajo-1500-pi.

Die Vorbedingung Check PLC Setting Camera on, correct electrode count wurde noch nicht erfüllt.


Generischer Prozessschritt vom Typ -nicht festgelegt-. Für den diesen Prozessschritt müssen ein oder mehrere Geräte aus der Kategorie: Automated handling device <d0d1e060>) ausgewählt werden. Für den diesen Prozessschritt müssen ein oder mehrere Objekte aus der Kategorie: Batteriekomponente <37da8604>) ausgewählt werden.



Prozessparameter

 ProzessObjektNameTypAttributWert
Anode magazine selectionStackingElectrodeStackAnodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor230504-jajo-0225-mi
Cathode magazine selectionStackingElectrodeStackCathodeMagazineSelectionParameter/Actual
Parameter/InputObject
HasPredecessor230504-jajo-0226-mi
Electrode image 01StackingElectrodeImage01Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0001.jpeg
Electrode image 02StackingElectrodeImage02Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0002.jpeg
Electrode image 03StackingElectrodeImage03Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0003.jpeg
Electrode image 04StackingElectrodeImage04Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0004.jpeg
Electrode image 05StackingElectrodeImage05Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0005.jpeg
Electrode image 06StackingElectrodeImage06Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0006.jpeg
Electrode image 07StackingElectrodeImage07Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0007.jpeg
Electrode image 08StackingElectrodeImage08Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0008.jpeg
Electrode image 09StackingElectrodeImage09Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0009.jpeg
Electrode image 10StackingElectrodeImage10Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0010.jpeg
Electrode image 11StackingElectrodeImage11Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0011.jpeg
Electrode image 12StackingElectrodeImage12Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0012.jpeg
Electrode image 13StackingElectrodeImage13Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0013.jpeg
Electrode image 14StackingElectrodeImage14Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0014.jpeg
Electrode image 15StackingElectrodeImage15Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0015.jpeg
Electrode image 16StackingElectrodeImage16Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0016.jpeg
Electrode image 17StackingElectrodeImage17Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0017.jpeg
Electrode image 18StackingElectrodeImage18Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0018.jpeg
Electrode image 19StackingElectrodeImage19Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0019.jpeg
Electrode image 20StackingElectrodeImage20Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0020.jpeg
Electrode image 21StackingElectrodeImage21Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0021.jpeg
Electrode image 22StackingElectrodeImage22Parameter/Actual
Parameter/File
Fabricated electrode backside image
HasFileOSL613be11b4c9847ea98c41ca412d01e32S0010P0022.jpeg
Predrying mass 01Stacking230504-jajo-1500-piPredryingMass01Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 02Stacking230504-jajo-1500-piPredryingMass02Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6430999999999996 g
Predrying mass 03Stacking230504-jajo-1500-piPredryingMass03Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass
Predrying mass 04Stacking230504-jajo-1500-piPredryingMass04Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6421000000000001 g
Predrying mass 05Stacking230504-jajo-1500-piPredryingMass05Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 06Stacking230504-jajo-1500-piPredryingMass06Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6438999999999999 g
Predrying mass 07Stacking230504-jajo-1500-piPredryingMass07Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 08Stacking230504-jajo-1500-piPredryingMass08Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6486000000000001 g
Predrying mass 09Stacking230504-jajo-1500-piPredryingMass09Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Predrying mass 10Stacking230504-jajo-1500-piPredryingMass10Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0.6520000000000001 g
Predrying mass 11Stacking230504-jajo-1500-piPredryingMass11Parameter/Actual
Parameter/Quantitative
Fabricated electrode predrying mass
Mass0 g
Separator selectionStackingElectrodeStackSeparatorSelectionParameter/Actual
Parameter/InputObject
HasPredecessor
ZFolder selectionStackingZFolderSelectionParameter/Actual
Parameter/DeviceTypeUsed
Parameter/DeviceUsed
Parameter/DeviceSetupUsed
HasToolType
HasTool
HasToolSetup
Z-Folder
Z-Folder (TKIII 004)

Dieser Prozessschritt ist definiert in: OslTemplate:LabProcess/Steps/Generic/Subpage